Condor HCS1 Hyrodem pH Control System
CO2 Dosing System with secondary pH testing and recirculation  
Water Treatment System with Absorption Sack and Coalescing media
Features: 
- auto control by pH controller P7635 with two adjustable control outputs 
- start-stop buttons for 0.37kW  mixer 
- flashing beacon and audible alarm for pH out of limits with mute button  
- level indicator/float switch located in final chamber to warn/stop low level recirculation  
Includes:
- surface mounting control panel
- 110V AC supply fitted door isolator power on lamp and e-stop button with 
- 24v AC control circuits containing off-auto switch for carbon dioxide valve 24v AC  
- 2 x pH sealed electrode systems c/w storage compartments to electrode wet  
- 2 x model SSV 0375-00 stainless steel solenoid valves with 24v AC coils pressure range 0-100 psi 
- 1 x model GMW11-SP2 geared mixer 0.37 kW motor with stainless steel shaft and impeller  
- 1 x 2 inch centrifugal recirculation pump 
Note: 
C02 to be procured separately
How does the Condor HCS Hydrodem operate? 
1. Waste is emptied into sack
Solids are retained, water percolates through liner of sack (sack to be replaced when full of solids)  
2. pH Probe measures pH in percolated water
High pH water will initialise carbon dioxide diffuser and agitator  
3. Water then passes through coalescing media, solids and precipitates fall to bottom of tank to be discharged via dump valve, water continues to final chamber
4. Water is tested by secondary pH Probe (parameters to be set by user), if pH in water is neutral water is discharged via 4 inch outlet
If the pH is high, the pH Probe will activate the recirculation pump and pump the contents of the final chamber back to be re-treated by carbon dioxide diffuser  
How does the Condor HCS Hydrodem operate? 
1. Waste is emptied into sack
Solids are retained, water percolates through liner of sack (sack to be replaced when full of solids)  
2. pH Probe measures pH in percolated water
High pH water will initialise carbon dioxide diffuser and agitator  
3. Water then passes through coalescing media, solids and precipitates fall to bottom of tank to be discharged via dump valve, water continues to final chamber
4. Water is tested by secondary pH Probe (parameters to be set by user), if pH in water is neutral water is discharged via 4 inch outlet
If the pH is high, the pH Probe will activate the recirculation pump and pump the contents of the final chamber back to be re-treated by carbon dioxide diffuser